Features

The 900-LFC Low-Frequency Control Element extends the response of mid-sized P.A. systems to 35 Hz
 

ACOUSTICAL1

Operating Frequency Range2

30 Hz 125 Hz

 

Frequency Response3

 

32 Hz 115 Hz ±4 dB

 

Phase Response

 

40 Hz 110 Hz ±30°

 

Linear Peak SPL4

 

133 dB with crest factor >10 dB (M-noise), 133 dB (Pink noise), 134.5 dB (B-noise)

COVERAGE

 

360° (single unit); varies with number of units and configurations

TRANSDUCERS

Low Frequency

One 18-inch, dual-coil, long-excursion cone driver; nominal impedance

AUDIO INPUT

Type

Differential, electronically balanced

 

Maximum Common Mode Range

 

±15 V DC, clamped to earth for voltage transient protection

 

Connectors5

 

XLR 5-pin female input with male loop output; XLR 3-pin female connectors available to accommodate only balanced audio (no RMS signals)

 

Input Impedance

 

10 differential between pins 2 and 3

 

 

 

Wiring

Pin 1: Chassis/earth through 1 kΩ, 1000 pF, 15 V clamped network to provide virtual ground lift at audio frequencies

Pin 2: Signal + Pin 3: Signal - Pin 4: RMS

Pin 5: RMS

 

Case: Earth ground and chassis

 

Nominal Input Sensitivity

 

6.0 dBV (2.0 V rms) continuous is typically the onset of limiting for noise and music

 

Input Level

Audio source must be capable of producing +20 dBV (10 V rms) into 600 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker

AMPLIFIER

Type

Two-channel, open-loop, class D

 

Total Output Power6

 

3100 W peak

 

THD, IM, TIM

 

< 0.02%

 

Cooling

 

Convection

AC POWER

Connectors

powerCON 20 input with loop output

 

Automatic Voltage Selection

 

90–265 V AC, 50–60 Hz

 

Safety Rated Voltage Range

 

100–240 V AC, 50–60 Hz

 

Turn-on and Turn-off Points

 

90 V AC turn-on, no turn-off; internal fuse-protection above 265 V AC

CURRENT DRAW

Idle Current

0.60 A rms (115 V AC), 0.49 A rms (230 V AC), 0.63 A rms (100 V AC)

 

Maximum Long-Term Continuous Current (>10 sec)

 

4.9 A rms (115 V AC); 2.5 A rms (230 V AC); 5.2 A rms (100 V AC)

 

Burst Current (<1 sec)7

 

8.8 A rms (115 V AC), 4.7 A rms (230 V AC), 11.0 A rms (100 V AC)

 

Maximum Instantaneous Peak Current

 

18.2 A peak (115 V AC), 9.2 A peak (230 V AC), 20.6 A peak (100 V AC)

 

Inrush Current

 

< 20 A peak

RMS NETWORK

 

Equipped with two-conductor twisted-pair network, reporting all operating parameters of amplifiers to system operator’s host computer.

  • Price only applicable for overseas
  • Technical Support
  • Term of shipment: Ex-Works
  • Pick up at Hoang Bao Khoa LTD company
  • All shipping costs and risks, including export/import procedures, duty and others are on buyer’s account (Incoterm 2020)

Contact

Business hours

Monday 7:30 AM - 5:00 PM
Tuesday 7:30 AM - 5:00 PM
Wednesday    7:30 AM - 5:00 PM
Thursday 7:30 AM - 5:00 PM
Friday 7:30 AM - 5:00 PM
Saturday 7:30 AM - 5:00 PM

FAQs

Does the company offer free shipping?

Free shipping for local order over $22. Oversea buyers will pay for shipping cost under Ex-work term.

900-LFC has a discount?

This price is the best to you now.

Which brand does 900-LFC belongs to?

900-LFC belongs to Meyer Sound. American speaker brand, the pride of American audio technology

How long is the warranty of 900-LFC?

900-LFC is 24 months of warranty.

Does HoangBaoKhoa support for installment?

Yes, installment payment via credit card.