             ACOUSTICAL 
             | 
        
        
            | 
             Operating Frequency Range1 
             | 
            
             30–140 Hz 
             | 
        
        
            | 
               
            Frequency Response2 
             | 
            
               
            32–123 Hz ±4 dB 
             | 
        
        
            | 
               
            Phase Response 
             | 
            
               
            40–123 Hz ±30° 
             | 
        
        
            | 
               
            Linear Peak SPL3 
             | 
            
               
            126 dB with crest factor >11.5 dB (M-noise), 126 dB (Pink noise), 127 dB (B-noise) 
             | 
        
        
            | 
               
            Coverage 
             | 
            
               
            360° (single unit),   varies with   number of   units and configuration 
             | 
        
        
            | 
             TRANSDUCERS 
             | 
        
        
            | 
             Low Frequency 
             | 
            
             Two 10-inch   cone drivers,   nominal impedance   4 & OMEGA; 
             | 
        
        
            | 
             AUDIO INPUT 
             | 
        
        
            | 
             Type 
             | 
            
             Differential, electronically   balanced 
             | 
        
        
            | 
               
            Maximum Common Mode Range 
             | 
            
               
            ±15 V DC, clamped to earth for voltage transient protection 
             | 
        
        
            | 
               
            Connectors4 
             | 
            
               
            XLR 3- or 5-pin female input with male loop output 
             | 
        
        
            | 
               
            Input Impedance 
             | 
            
               
            10 kΩ   differential between   pins 2 and 3 
             | 
        
        
            | 
               
              
            Wiring 
             | 
            
             Pin 1: Chassis/earth through 1 kΩ, 1000 pF, 15 V clamp network to provide virtual ground lift at audio frequencies 
            Pin 2: Signal + Pin 3: Signal - 
            Case: Earth ground and chassis 
             | 
        
        
            | 
               
            Nominal Input Sensitivity 
             | 
            
               
            0 dBV (1 V rms) continuous is typically the onset of limiting for noise and music 
             | 
        
        
            | 
               
            Input Level 
             | 
            
               
            Audio source must be capable of producing a minimum of +20 dBV (10 V rms) into 600 Ω to produce maximum peak SPL over the operating bandwidth of the speaker 
             | 
        
        
            | 
             AMPLIFIERS 
             | 
        
        
            | 
             Type 
             | 
            
             2-channel (class D) with crossover 
             | 
        
        
            | 
               
            Total Output Power5 
             | 
            
               
            1800 W peak 
             | 
        
        
            | 
               
            THD, IM, TIM 
             | 
            
               
            < 0.02% 
             | 
        
        
            | 
               
            Load 
             | 
            
               
            4 Ω   per channel 
             | 
        
        
            | 
               
            Cooling 
             | 
            
               
            Convection 
             | 
        
        
            | 
             AC POWER 
             | 
        
        
            | 
             Connector 
             | 
            
             powerCON 20 input with loop output 
             | 
        
        
            | 
               
            Automatic Voltage Selection 
             | 
            
               
            Automatic 
             | 
        
        
            | 
               
            Safety Agency Rated Operating Range 
             | 
            
               
            100–240 V AC, 50–60 Hz 
             | 
        
        
            | 
               
            Turn-on and Turn-off Points 
             | 
            
               
            90 V AC turn-on, no turn-off; internal fuse-protection above 265 V AC 
             | 
        
        
            | 
             CURRENT DRAW 
             | 
        
        
            | 
             Idle Current 
             | 
            
             0.27 A rms (115 V AC); 0.25 A rms (230 V AC); 0.29 A rms (100 V AC) 
             | 
        
        
            | 
               
            Max Long-Term Continuous Current (>10 sec) 
             | 
            
               
            1.4 A rms (115 V AC); 0.7 A rms (230 V AC); 1.6 A rms (100 V AC) 
             | 
        
        
            | 
               
            Burst Current (<1 sec)6 
             | 
            
               
            4.5 A rms (115 A AC); 2.1 A rms (230 V AC); 4.8 A rms (100 V AC) 
             | 
        
        
            | 
               
            Maximum Instantaneous Peak Current 
             | 
            
               
            9.7 A peak (115 V AC); 4.6 A peak (230 V AC); 10.8 A peak (100 V AC) 
             | 
        
        
            | 
               
            Inrush Current 
             | 
            
               
            <20 A peak 
             |