ACOUSTICAL1
|
Operating Frequency Range2
|
42 Hz – 22 kHz
|
Frequency Response
|
45 Hz – 20 kHz ± 4 dB
|
Phase Response
|
190 Hz – 20 kHz ±45°
|
Linear Peak SPL3
|
120.5 dB with >18.5 dB crest factor (M-noise), 117.5 dB (Pink noise), 120 dB (B‑noise)
|
COVERAGE
|
Horizontal Coverage
|
80°
|
Vertical Coverage
|
50°
|
TRANSDUCERS
|
Low Frequency
|
One 6.5‑inch long‑excursion cone driver; 4 Ω nominal impedance
|
High Frequency
|
One 1‑inch dome tweeter on a constant‑directivity waveguide; 4 Ω nominal impedance
|
AUDIO INPUT
|
Type
|
Differential, electronically balanced
|
Maximum Common Mode Range
|
±15 V DC
|
Connectors
|
XLR 3‑pin female input with male loop output.
|
Input Impedance
|
10 kΩ differential between pins 2 and 3
|
Wiring
|
Pin 1: Chassis/earth through 1 kΩ, 1000 pF, 15 V clamp network to provide virtual ground lift at audio frequencies
Pin 2: Signal + Pin 3: Signal –
Case: Earth ground and chassis
|
Nominal Input Sensitivity
|
6 dBV (2.0 V rms) continuous is typically the onset of limiting for noise and music
|
Input Level
|
Audio source must be capable of producing of +20 dBV (10 V rms) into 600 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker.
|
AMPLIFIER
|
Type
|
Two‑channel, Class‑D
|
Total Output Power4
|
900 W peak
|
THD, IM, TIM
|
< 0.02%
|
Cooling
|
Convection
|
AC POWER
|
Connector
|
powerCON 20 input with loop output (up to 7 Amie loudspeakers may be safely looped)
|
Automatic Voltage Selection
|
90–265 V AC
|
Safety Agency Rated Voltage Range
|
100–240 V AC, 50–60 Hz
|
Turn‑on and Turn‑off Points
|
90 V AC turn‑on, no turn‑off; internal fuse‑protection above 265 V AC
|
CURRENT DRAW
|
Idle Current
|
0.160 A rms (115 V AC); 0.144 A rms (230 V AC); 0.183 A rms (100 V AC)
|
Maximum Long‑Term Continuous Current (>10 sec)
|
0.68 A rms (115 V AC); 0.36 A rms (230 V AC); 0.79 A rms (100 V AC)
|
Burst Current (<1 sec)5
|
1.02 A rms (115 V AC), 0.51 A rms (230 V AC), 1.2 A rms (100 V AC)
|
Maximum Instantaneous Peak Current
|
2.7 A peak (115 V AC), 1.4 A peak (230 V AC), 3.1 A peak (100 V AC)
|
Inrush Current
|
<20.0 A peak
|