             ACOUSTICAL1 
             | 
        
        
            | 
             Operating Frequency Range2 
             | 
            
             75 Hz – 20 kHz 
             | 
        
        
            | 
               
            Frequency Response3 
             | 
            
               
            80 Hz   – 16 kHz ±4 dB 
             | 
        
        
            | 
               
            Phase Response 
             | 
            
               
            415 Hz   – 16 kHz  ±45° 
             | 
        
        
            | 
               
            Linear Peak SPL4 
             | 
            
               
            118.5 dB with crest factor >14 dB (M-noise), 113 dB (Pink noise), 115.5 (B-noise) 
             | 
        
        
            | 
             COVERAGE 
             | 
        
        
            | 
             Horizontal Coverage 
             | 
            
             100° 
             | 
        
        
            | 
               
            Vertical Coverage 
             | 
            
               
            100° 
             | 
        
        
            | 
             TRANSDUCERS 
             | 
        
        
            | 
             Low Frequency5 
             | 
            
             Two 5-inch   cone drivers;   8 Ω nominal impedance 
             | 
        
        
            | 
               
            High Frequency 
             | 
            
               
            One 1-inch metal dome tweeter; 8 Ω nominal impedance 
             | 
        
        
            | 
             AUDIO INPUT 
             | 
        
        
            | 
             Type 
             | 
            
             Differential, electronically   balanced 
             | 
        
        
            | 
               
            Maximum Common Mode Range 
             | 
            
               
            ±15 V DC, clamped to earth for voltage transient protection 
             | 
        
        
            | 
               
            Connectors 
             | 
            
               
            XLR 3-pin female input with male loop output; optional 5-pin connectors accommodate both balanced audio and   RMS signals. 
             | 
        
        
            | 
               
            Input Impedance 
             | 
            
               
            10 k& OMEGA;   differential between   pins 2 and 3 
             | 
        
        
            | 
               
              
            Wiring 
             | 
            
             Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamp network to provide virtual ground lift at audio frequencies 
            Pin 2: Signal + Pin 3: Signal – 
            Case: Earth ground and chassis 
             | 
        
        
            | 
               
            Nominal Input Sensitivity 
             | 
            
               
            0 dBV (1.0 V rms) continuous is typically the onset of limiting for noise and music 
             | 
        
        
            | 
               
            Input Level 
             | 
            
               
            Audio source must be capable of producing of +20 dBV (10 V rms) into 600 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker. 
             | 
        
        
            | 
             AMPLIFIER 
             | 
        
        
            | 
             Type 
             | 
            
             Complementary MOSFET output   stages (class AB/bridged) 
             | 
        
        
            | 
               
            Total Output Power6 
             | 
            
               
            650 W peak 
             | 
        
        
            | 
               
            THD, IM, TIM 
             | 
            
               
            < 0.02% 
             | 
        
        
            | 
               
            Cooling 
             | 
            
               
            Convection 
             | 
        
        
            | 
             AC POWER 
             | 
        
        
            | 
             Connector 
             | 
            
             powerCON input with loop output 
             | 
        
        
            | 
               
            Voltage Selection 
             | 
            
               
            External 115/230 V AC switch (100 V AC version available)7 
             | 
        
        
            | 
               
            Safety Rated Voltage Range 
             | 
            
               
            Input rating: 115/230 V AC, 50–60 Hz, 3 A MAX; 
            Loop output rating:   115/230 V   AC, 50–60   Hz, 12 A MAX 
             | 
        
        
            | 
               
            Turn-on and Turn-off Points 
             | 
            
               
            Fuse-protected above 135 V AC (115 V AC switch position) and   265 V AC (230 V AC switch position) 
             | 
        
        
            | 
             CURRENT DRAW 
             | 
        
        
            | 
             Idle Current 
             | 
            
             0.13 A rms (115 V AC); 0.065 A rms (230 V AC); 0.15 A rms (100 V AC) 
             | 
        
        
            | 
               
            Maximum Long-Term Continuous Current (> 10 sec) 
             | 
            
               
            1 A rms (115 V AC); 0.5 A rms (230 V AC); 1.2 A rms (100 V AC) 
             | 
        
        
            | 
               
            Burst Current (< 1 sec)8 
             | 
            
               
            1.3 A rms  (115 V AC); 0.65 A rms (230 V AC); 1.5 A rms (100 V AC) 
             | 
        
        
            | 
               
            Maximum Instantaneous Peak Current 
             | 
            
               
            2.9 A pk (115 V AC); 2 A pk (230 V AC); 3.3 A pk (100 V AC) 
             | 
        
        
            | 
               
            Inrush Current 
             | 
            
               
            18 A pk (115 V AC); 12 A pk (230 V AC); 15 A pk (100 V AC) 
             |