Operating Frequency Range2
|
|
|
|
|
143.5 dB with crest factor >17.5 dB (M-noise),
137.5 dB (Pink noise),
140 dB (B-noise)
|
143.5 dB with crest factor >17.5 dB (M-noise),
136.5 dB (Pink noise), 138.5 dB (B-noise)
|
143.5 dB with crest factor> 17.5 dB (M-noise), 136.5 dB (Pink noise), 138.5 dB (B-noise)
|
|
|
|
|
|
|
|
|
|
Varies, depending on array length and configuration; LYON-WXT has extended vertical coverage.
|
|
|
Two 12-inch long-excursion cone drivers; 4 Ω nominal impedance
|
|
Two 3-inch diaphragm compression drivers coupled to a constant-directivity horn through a patented REM manifold; 16 Ω nominal impedance
|
|
|
Differential, electronically balanced
|
Maximum Common Mode Range
|
±15 V DC, clamped to earth for voltage transient protection
|
|
XLR 5-pin female input with male loop output; XLR 3-pin female connectors available to accommodate only balanced audio (no RMS signals)
|
|
10 kΩ differential between pins 2 and 3
|
|
Pin 1: Chassis/earth through 1 kΩ, 1000 pF, 15 V clamped network to provide virtual ground lift at audio frequencies
Pin 2: Signal +
Pin 3: Signal -
Pin 4: RMS
Pin 5: RMS
Case: Earth ground and chassis
|
Nominal Input Sensitivity
|
0 dBV (1 V rms) continuous is typically the onset of limiting for noise and music
|
|
Audio source must be capable of producing of +20 dBV (10 V rms) into 50 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker.
|
|
|
3-channel complementary MOSFET output stages (class AB/H bridged)
|
|
|
|
|
|
Two ultra high-speed primary fans; two ultra high-speed reserve fans
|
|
|
|
Automatic Voltage Selection
|
95–125 V AC, 50–60 Hz; 208–235 V AC, 50–60 Hz
|
Safety Rated Voltage Range
|
|
Turn-on and Turn-off Points
|
Turn-on: 85 V AC; Turn-off: 134 V AC; Turn-on: 165 V AC; Turn-off: 264 V AC
|
|
|
1.2 A rms (115 V AC); 0.6 A rms (230 V AC); 0.7 A rms (208 V AC)
|
Max Long-Term Continuous Current (>10 sec)
|
11.2 A rms (115 V AC); 5.6 A rms (230 V AC); 6.2 A rms (208 V AC)
|
|
15.4 A rms (115 V AC); 7.5 A rms (230 V AC); 8.2 A rms (208 V AC)
|
Maximum Instantaneous Peak Current
|
45 A peak (115 V AC); 23 A peak (230 V AC); 25 A peak (208 V AC)
|
|
|