ACOUSTICAL1
|
Operating Frequency Range2
|
13–35 Hz
|
Frequency Response3
|
13–30 Hz ±4 dB
|
Phase Response
|
13–30 Hz ±30°
|
Linear Peak SPL4
|
125.5 dB with crest factor >10.5 dB (M-noise), 125.5 dB (Pink noise)
|
COVERAGE
|
|
360° (single unit); varies with number of units and configuration
|
TRANSDUCERS
|
Low Frequency
|
Two 18‑inch long‑excursion low‑resonance cone drivers; 8 Ω nominal impedance
|
AUDIO INPUT
|
Type
|
Differential, electronically balanced
|
Maximum Common Mode Range
|
±15 V DC, clamped to earth for voltage transient protection
|
Connectors
|
XLR 5‑pin female input with male loop output; XLR 3‑pin female connectors available to accommodate only balanced audio (no RMS signals)
|
Input Impedance
|
10 kΩ differential between pins 2 and 3
|
Wiring5
|
Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamp network to provide virtual ground lift at audio frequencies
Pin 2: Signal + Pin 3: Signal ‑ Pin 4: RMS
Pin 5: RMS
Case: Earth ground and chassis
|
Nominal Input Sensitivity
|
0 dBV (1.0 V rms) continuous is typically the onset of limiting for noise and music
|
Input Level
|
Audio source must be capable of producing +20 dBV (10 V rms) into 600 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker
|
AMPLIFIER
|
Type
|
2‑channel complementary MOSFET output stages (Class AB/H bridged)
|
Total Output Power6
|
5600 W peak
|
THD, IM, TIM
|
< 0.02%
|
Cooling
|
Three ultra high‑speed primary fans; three ultra high‑speed reserve fans
|
AC POWER
|
Connectors
|
powerCON 32 input
|
Automatic Voltage Selection
|
208–235 V AC, 50/60 Hz
|
Safety Rated Voltage Range
|
208–235 V AC, 50/60 Hz
|
Turn‑on and Turn‑off Points
|
165 V AC turn‑on; 264 V AC turn‑off
|
CURRENT DRAW
|
Idle Current
|
0.6 A rms (230 V AC)
|
Maximum Long‑Term Continuous Current (>10 sec)
|
10.5 A rms (230 V AC)
|
Burst Current (<1 sec)7
|
18 A rms (230 V AC)
|
Maximum Instantaneous Peak Current
|
53 A peak (230 V AC)
|
Inrush Current
|
< 30 A peak
|
RMS NETWORK
|
|